load control - preturi si oferte
Anunta-ma cand apar noutati despre load control
Alertele sunt emailuri care se trimit gratuit in fuctie de preferintele tale. Contin atat update-uri cat si noutati despre produsele si cuvintele cheie pe care le doresti.
AN7135
amplifier 2x7,5W Maximal output power @Load resistance: 2x7,5W@3Ohm Bandwidth: 20Hz-20 ... »
Convertor tensiune DC-DC SD-15A-05
.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise, hold up time: 2.5s..., 25ms,--- 12VDC/24VDC/48VDC at full load Voltage range: A:9.2 ~18VDC, B:18 ~ 36VDC... load: 105% -160% rated output power, Protection type : hiccup mode , recovers ... »
Convertor tensiune DC-DC SD-15B-05
.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise, hold up time: 2.5s..., 25ms,--- 12VDC/24VDC/48VDC at full load Voltage range: A:9.2 ~18VDC B:18 ~ 36VDC... load: 105% -160% rated output power, Protection type : hiccup mode , recovers ... »
Convertor tensiune DC-DC SD-15C-05
.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise, hold up time: 2.5s..., 25ms,--- 12VDC/24VDC/48VDC at full load Voltage range: A:9.2 ~18VDC B:18 ~ 36VDC... load: 105% -160% rated output power, Protection type : hiccup mode , recovers ... »
Convertor tensiune DC-DC SD-15A-12
: +/- 1.0% Line regulation: +/- 0.3% Load regulation: +/- 0.3% Setup, rise, hold up... time: 2.5s, 25ms,--- 12VDC/24VDC/48VDC at full load Voltage range: A:9.2 ~18VDC B.../48VDC Over load: 105% -160% rated output power, Protection type : hiccup mode ... »
Convertor tensiune DC-DC SD-15B-12
: +/- 1.0% Line regulation: +/- 0.3% Load regulation: +/- 0.3% Setup, rise, hold up... time: 2.5s, 25ms,--- 12VDC/24VDC/48VDC at full load Voltage range: A:9.2 ~18VDC B.../48VDC Over load: 105% -160% rated output power, Protection type : hiccup mode ... »
Convertor tensiune DC-DC SD-15C-12
: +/- 1.0% Line regulation: +/- 0.3% Load regulation: +/- 0.3% Setup, rise, hold up... time: 2.5s, 25ms,--- 12VDC/24VDC/48VDC at full load Voltage range: A:9.2 ~18VDC B.../48VDC Over load: 105% -160% rated output power, Protection type : hiccup mode ... »
Convertor tensiune DC-DC SD-15A-24
tolerance: +/- 1.0% Line regulation: +/- 0.2% Load regulation: +/- 0.2% Setup, rise..., hold up time: 2.5s, 25ms,--- 12VDC/24VDC/48VDC at full load Voltage range: A:9... 0.45A/48VDC Over load: 105% -160% rated output power, Protection type : hiccup ... »
Convertor tensiune DC-DC SD-15B-24
tolerance: +/- 1.0% Line regulation: +/- 0.2% Load regulation: +/- 0.2% Setup, rise..., hold up time: 2.5s, 25ms,--- 12VDC/24VDC/48VDC at full load Voltage range: A:9... 0.45A/48VDC Over load: 105% -160% rated output power, Protection type : hiccup ... »
Convertor tensiune DC-DC SD-15C-24
tolerance: +/- 1.0% Line regulation: +/- 0.2% Load regulation: +/- 0.2% Setup, rise..., hold up time: 2.5s, 25ms,--- 12VDC/24VDC/48VDC at full load Voltage range: A:9... 0.45A/48VDC Over load: 105% -160% rated output power, Protection type : hiccup ... »
Sursa laborator 18V 3A
≤0.2%±1mA Load effect: CV≤0.01%±5mV, CC≤0.2%±5m ... »
AN17850A
@ Load 44W x 2 @ 6 Ohm Lead Free Status Lead Free RoHS Status RoHS Compliant Other ... »
AN7112E
power @Load resistance: 500mW@8Ohm Bandwidth: 40Hz-18KHz Supply voltage: Min: 4V Max ... »
Invertor tensiune 12V la 220V 1500W
, repornire dupa recuperare Supraincarcare (typ.): 105 ~ 115% load for 180 sec., 115...% ~ 150% load for 10 sec. Mod de protectie : Inchidere o/p voltage, repornire dupa ... »
Invertor tensiune si incarcator solar 48V la 220V 1500W
.): 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Mod de protectie ... »
Invertor tensiune si incarcator solar 24V la 220V 1500W
.): 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Mod de protectie ... »
Invertor tensiune si incarcator solar 12V la 220V 1500W
.): 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Mod de protectie ... »
Invertor tensiune 48V la 220V 700W
, repornire dupa recuperare Supraincarcare (typ.): 105 ~ 115% load for 180 sec., 115...% ~ 150% load for 10 sec. Mod de protectie : Inchidere o/p voltage, repornire dupa ... »
Invertor tensiune 24V la 220V 700W
, repornire dupa recuperare Supraincarcare (typ.): 105 ~ 115% load for 180 sec., 115...% ~ 150% load for 10 sec. Mod de protectie : Inchidere o/p voltage, repornire dupa ... »
Invertor tensiune 12V la 220V 700W
, repornire dupa recuperare Supraincarcare (typ.): 105 ~ 115% load for 180 sec., 115...% ~ 150% load for 10 sec. Mod de protectie : Inchidere o/p voltage, repornire dupa ... »
Invertor tensiune 24V la 220V 1500W
, repornire dupa recuperare Supraincarcare (typ.): 105 ~ 115% load for 180 sec., 115...% ~ 150% load for 10 sec. Mod de protectie : Inchidere o/p voltage, repornire dupa ... »
Invertor tensiune 48V la 220V 1500W
, repornire dupa recuperare Supraincarcare (typ.): 105 ~ 115% load for 180 sec., 115...% ~ 150% load for 10 sec. Mod de protectie : Inchidere o/p voltage, repornire dupa ... »
UPS 1500VA led cu AVR
: 10 ~ 20 Minutes, Depending on Load General Transformer: Toroidal Transformer (New..., no electromagnetic interference to load. Self-detection on startup. Battery replaceable without ... »
UPS 1200VA LED cu AVR
: 10 ~ 20 Minutes, Depending on Load General Transformer: Toroidal Transformer (New..., no electromagnetic interference to load. Self-detection on startup. Battery replaceable without ... »
UPS 1000VA LED cu AVR
: 10 ~ 20 Minutes, Depending on Load General Transformer: Toroidal Transformer (New..., no electromagnetic interference to load. Self-detection on startup. Battery replaceable without ... »

