Sursa in comutatie AC-DC 24V 1.1A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 1200...ms, 23ms/230VAC 2200ms, 30ms/115VAC at full load Hold up time (Typ.): 80ms/230VAC... 14ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300 ... »
Sursa in comutatie AC-DC 48V 0.57A
tolerance: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time...: 1200ms, 23ms/230VAC 2200ms, 30ms/115VAC at full load Hold up time (Typ.): 80ms/230...VAC 14ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand ... »
Sursa in comutatie AC-DC 3.3V 7A
: +/- 3.0% Line regulation: +/- 0.5% Load regulation: +/- 2.0% Setup, rise time: 500ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 80ms/230VAC 15...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 5V 7A
.0% Line regulation: +/- 0.5% Load regulation: +/- 1.0% Setup, rise time: 500ms, 30ms.../230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 80ms/230VAC 15ms/115...VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge ... »
Sursa in comutatie AC-DC 12V 3A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 500ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 80ms/230VAC 15...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 15V 3A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 500ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 80ms/230VAC 15...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 24V 1.5A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 500ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 80ms/230VAC 15...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 48V 0.8A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 500ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 80ms/230VAC 15...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 3.3V 10A
: +/- 3.0% Line regulation: +/- 0.5% Load regulation: +/- 2.0% Setup, rise time: 500ms..., 20ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 60ms/230VAC 14...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 5V 10A
: +/- 2.0% Line regulation: +/- 0.5% Load regulation: +/- 1.0% Setup, rise time: 500ms..., 20ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 60ms/230VAC 14...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 12V 4.2A
tolerance: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time...: 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 60ms/230...VAC 14ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand ... »
Sursa in comutatie AC-DC 15V 3.4A
tolerance: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time...: 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 60ms/230...VAC 14ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand ... »
Sursa in comutatie AC-DC 48V 1.1A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 500ms..., 20ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 60ms/230VAC 14...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 3.3V 15A
: +/- 3.0% Line regulation: +/- 0.5% Load regulation: +/- 2.0% Setup, rise time: 500ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 60ms/230VAC 14...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 5V 12A
: +/- 2.0% Line regulation: +/- 0.5% Load regulation: +/- 1.0% Setup, rise time: 500ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 60ms/230VAC 14...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 12V 6A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 500ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 60ms/230VAC 14...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 15V 5A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 500ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 60ms/230VAC 14...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 24V 3.2A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 500ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 60ms/230VAC 14...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 48V 1.6A
: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time: 500ms..., 30ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 60ms/230VAC 14...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 3.3V 20A
: +/- 3.0% Line regulation: +/- 0.5% Load regulation: +/- 2.0% Setup, rise time: 500ms..., 20ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 100ms/230VAC 18...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 5V 16A
: +/- 2.0% Line regulation: +/- 0.5% Load regulation: +/- 1.0% Setup, rise time: 500ms..., 20ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 100ms/230VAC 18...ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC ... »
Sursa in comutatie AC-DC 12V 8.5A
tolerance: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time...: 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 100ms/230...VAC 18ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand ... »
Sursa in comutatie AC-DC 15V 7A
tolerance: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time...: 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 100ms/230...VAC 18ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand ... »
Sursa in comutatie AC-DC 24V 4.5A
tolerance: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time...: 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 100ms/230...VAC 18ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand ... »
Sursa in comutatie AC-DC 48V 2.3A
tolerance: +/- 1.0% Line regulation: +/- 0.5% Load regulation: +/- 0.5% Setup, rise time...: 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load Hold up time (Typ.): 100ms/230...VAC 18ms/115VAC at full load Voltage range: 88 ~ 264VAC 125 ~ 373VDC (Withstand ... »