cli8y - preturi si oferte
Anunta-ma cand apar noutati despre cli8y
Alertele sunt emailuri care se trimit gratuit in fuctie de preferintele tale. Contin atat update-uri cat si noutati despre produsele si cuvintele cheie pe care le doresti.
Sursa in comutatie AC-DC 15V 1.7A
, period for 60min. each along X, Y, Z axes Safety standards: UL60950-1, TUV EN60950...61000-3-2,-3 Ems immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light ... »
Sursa alimentare fara carcasa 15V 1.7A
min.each along X, Y, Z axes Safety standards: EN60950-1 CB Approved by TUV...: Compliance to EN61000-4-2,3,4,5,6,8,11 Light industry level, criteria A Mtbf: 576.4Khrs ... »
Sursa alimentare fara carcasa 24V 1A
min.each along X, Y, Z axes Safety standards: EN60950-1 CB Approved by TUV...: Compliance to EN61000-4-2,3,4,5,6,8,11 Light industry level, criteria A Mtbf: 576.4Khrs ... »
Sursa alimentare fara carcasa 27V 0.9A
min.each along X, Y, Z axes Safety standards: EN60950-1 CB Approved by TUV...: Compliance to EN61000-4-2,3,4,5,6,8,11 Light industry level, criteria A Mtbf: 576.4Khrs ... »
Sursa in comutatie AC-DC 5V 5A
) Vibration: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes...61000-4-2,3, 4,5; ENV50204, EN55024, Light industry level, criteria A Mtbf: 330.8K ... »
Sursa in comutatie AC-DC 15V 1.7A
) Vibration: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes...61000-4-2,3, 4,5; ENV50204, EN55024, Light industry level, criteria A Mtbf: 330.8K ... »
Sursa in comutatie AC-DC 24V 1.1A
) Vibration: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes...61000-4-2,3, 4,5; ENV50204, EN55024, Light industry level, criteria A Mtbf: 330.8K ... »
Sursa in comutatie AC-DC 5V 12A
: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Vibration... immunity: Compliance to EN61000-4-2,3, 4,5,6,8,11; ENV50204, EN55024, light industry ... »
Sursa in comutatie AC-DC 5V 20A
: 0.03%/ (0 ~ 50 Vibration: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y...: Compliance to EN61000-3-2,-3 Ems immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV ... »
Sursa in comutatie AC-DC 15V 4A
: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Vibration... immunity: Compliance to EN61000-4-2,3, 4,5,6,8,11; ENV50204, EN55024, light industry ... »
Sursa in comutatie AC-DC 24V 2.4A
: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Vibration... immunity: Compliance to EN61000-4-2,3, 4,5,6,8,11; ENV50204, EN55024, light industry ... »
Sursa in comutatie AC-DC 15V 6.7A
: 0.03%/ (0 ~ 50 Vibration: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y...: Compliance to EN61000-3-2,-3 Ems immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV ... »
Sursa in comutatie AC-DC 24V 4.5A
: 0.03%/ (0 ~ 50 Vibration: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y...: Compliance to EN61000-3-2,-3 Ems immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV ... »
Sursa in comutatie AC-DC 5V 30A
C) Vibration: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes... immunity: Compliance to EN61000-4-2,3, 4,5,6,8,11; ENV50204, EN55024, Light indust ry ... »
Sursa in comutatie AC-DC 13.5V 11.2A
cycle, 60min. each along X, Y, Z axes Safety standards: UL1012, UL60950-1, TUV EN...61000-3-2,-3 Harmonic current ems immunity: Compliance to EN61000-4-2,3, 4,5,6,8 ... »
Sursa in comutatie AC-DC 15V 10A
C) Vibration: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes... immunity: Compliance to EN61000-4-2,3, 4,5,6,8,11; ENV50204, EN55024, Light indust ry ... »
Sursa in comutatie AC-DC 27V 5.6A
C) Vibration: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes... immunity: Compliance to EN61000-4-2,3, 4,5,6,8,11; ENV50204, EN55024, Light indust ry ... »
Sursa in comutatie AC-DC 5V 5A
, period for 60min. each along X, Y, Z axes Safety standards: UL60950-1, TUV EN60950...61000-3-2,-3 Ems immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light ... »
Sursa in comutatie AC-DC 24V 1.1A
, period for 60min. each along X, Y, Z axes Safety standards: UL60950-1, TUV EN60950...61000-3-2,-3 Ems immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, light ... »
Sursa in comutatie AC-DC 5V 12A
min. each along X, Y, Z axes Safety standards: UL60950-1, TUV EN60950-1 approved... immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, heavy industry level ... »
Sursa in comutatie AC-DC 15V 5A
min. each along X, Y, Z axes Safety standards: UL60950-1, TUV EN60950-1 approved... immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, heavy industry level ... »
Sursa in comutatie AC-DC 5V 26A
, period for 60min. each along X, Y, Z axes Safety standards: UL60950-1, TUV EN60950...-3-2,-3 Ems immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, heavy industry ... »
Sursa in comutatie AC-DC 15V 10A
, period for 60min. each along X, Y, Z axes Safety standards: UL60950-1, TUV EN60950...-3-2,-3 Ems immunity: Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, heavy industry ... »
Convertor tensiune DC-DC SD-150C-24
min.each along X, Y, Z axes Safety standards: EN60950-1 CB Approved by TUV (for D...; radiation: Compliance to EN55022 (CISPR22) Class B Ems immunity: Compliance to EN61000-4-2,3,4,6,8 ... »
Convertor tensiune DC-DC SD-150D-24
min.each along X, Y, Z axes Safety standards: EN60950-1 CB Approved by TUV (for D...; radiation: Compliance to EN55022 (CISPR22) Class B Ems immunity: Compliance to EN61000-4-2,3,4,6,8 ... »
563711 produse / 22549 pagini
25 produse pe pagina.
"cli8y" in Firme Hot - 875 Rezultat(e)

